CABLES

Product Name Appllcation Standards
XHHW-2 XHHW-2 building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). ASTM B3, B8;UL 44;USA National Electrical Code, NFPA 70, 2014 Edition
XHHW XHHW building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). ASTM B3, B8;UL 44;USA National Electrical Code, NFPA 70, 2014 Edition
XHH XHH building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). ASTM B3, B8;UL 44;USA National Electrical Code, NFPA 70, 2014 Edition
RHW-2 600V RHW-2 is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B3, B8;UL 44;USA National Electrical Code, NFPA 70, 2014 Edition
RHW 600V RHW is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B3, B8;UL 44;USA National Electrical Code, NFPA 70, 2014 Edition
RHH 600V RHH soft-annealed uncoated copper conductor is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B3, B8;UL 44;USA National Electrical Code, NFPA 70, 2014 Edition
XHHW-2 AL XHHW-2 AL building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836;UL 44USA National Electrical Code, NFPA 70, 2014 Edition
XHHW AL XHHW AL building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836;UL 44USA National Electrical Code, NFPA 70, 2014 Edition
XHH AL XHH AL building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836;UL 44USA National Electrical Code, NFPA 70, 2014 Edition
RHW-2 AL 600V RHW-2 with aluminum alloy 8000 series conductors are suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836;UL 44USA National Electrical Code, NFPA 70, 2014 Edition
RHW AL 600V RHW with aluminum alloy 8000 series conductors are suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836;UL 44USA National Electrical Code, NFPA 70, 2014 Edition
RHH AL RHH with aluminum alloy 8000 series conductors are suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836;UL 44USA National Electrical Code, NFPA 70, 2014 Edition
THWN-2 THWN-2 is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B3, B8;UL;83
THWN THWN is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications.  ASTM B3, B8;UL;83
THHW THHW is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B3, B8;UL 83
THHN THHN is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications.  ASTM B3, B8;UL 83
THW-2 THW-2 is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications ASTM B3, B8UL 83
THW THW is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B3, B8 UL 83
TW TW is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B3, B8 UL 83
THWN-2 AL THWN-2 building wire with aluminum alloy 8000 series conductors are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications.  ASTM B800, B801,B836                                                                     UL 83
THWN AL THWN building wire with aluminum alloy 8000 series conductors are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B800, B801,B836; UL 83
THHN AL THHN building wire with aluminum alloy 8000 series are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B800, B801,B836; UL 83
THW-2 AL THW-2 building wire with aluminum alloy 8000 series conductors are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B800, B801,B836; UL 83
THW AL THW building wire with aluminum alloy 8000 series conductors are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B800, B801,B836; UL 83
THHW AL THHW building wire with aluminum alloy 8000 series conductors are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B800, B801,B836; UL 83
TW AL TW building wire with aluminum alloy 8000 series conductors are intended for general purpose applications as defined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial new construction or rewiring for 600 volt applications. ASTM B800, B801,B836; UL 83
Single Conductor USE-2 USE-2cable is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTMB3,B8,B787; UL 854
Single Conductor USE USE cable is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTMB3,B8,B787; UL 854
Single Conductor USE-2 AL USE-2 cable with single 8000 Series or 1350-H19 Aluminum Alloy conductor is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836, B230, B230M-07   UL854; USA National Electrical Code/NFPA 70, 2014Edition
Single Conductor USE AL USE cable with single 8000 Series or 1350-H19 Aluminum Alloy conductor is suitable for use in conduit and raceways installed underground in conduit as specified in the USA National Electrical Code (NEC) ASTM B800, B801, B836, B230, B230M-07   UL854; USA National Electrical Code/NFPA 70, 2014Edition
Single Conductor URD/USE-2 Secondary UD cable with single 1350-H19 Aluminum conductor suitable for use in underground service and secondary distribution ASTM B230,(B231, B609,B901); ICEA S-105-692    UL854
Multicore Conductor URD/USE-2 Secondary UD cable with 1350-H19 Aluminum conductor suitable for use in underground service and secondary distribution, Neutrals are identified by triple yellow stripe extrusion. ASTM B230,(B231, B609,B901); ICEA S-105-692    UL854
SE-U with XHHW-2 Inners SE-U (Service Entrance Cable Style U) is used to convey power from the service drop to the meter base and from the meter base to the distribution panel board; however, it may be used in all applications where SE-U is permitted. ASTMB3, B8; UL 44(UL83/UL854);UL854
SE-U with XHHW-2 AL Inners SE-U AL (Aluminum Alloy Conductor Service Entrance Cable Style U) is used to convey power from the service drop to the meter base and from the meter base to the distribution panel board; however, it may be used in all applications where SE-U AL cable is permitted. ASTM B800, B801, B836; UL 44(UL83/UL854); UL 854; USA National Electrical Code, NFPA 70, 2014 Edition
SE-R with XHHW-2 Inners SE-R (Service Entrance Cable Style R) is used to convey power from the service drop to the meter base and from the meter base to the distribution panel board; however, it may be used in all applications where SE-R cable is permitted. ASTMB3, B8; UL 44(UL83/UL854);UL854
SE-R with XHHW-2 AL Inners SE-R AL (Aluminum Alloy Conductor -Service Entrance Cable Style R) is used to convey power from the service drop to the meter base and from the meter base to the distribution panel board; however, it may be used in all applications where SE-R AL cable is permitted. ASTM B800, B801, B836; UL 44(UL83/UL854); UL 854; USA National Electrical Code, NFPA 70, 2014 Edition
UF-B Type UF-B (Underground Feeder Cable) is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building. UF-B may be used underground, including direct burial. ASTM B-3 and B-8; UL 83; UL 493
UF (Flat) Type UF (Underground Feeder Cable) is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building. UF may be used underground, including direct burial. ASTM B-3 and B-8; UL 83; UL 493
NM-B (Round) NM-B is commonly used for residential wiring of luminaries, devices and appliances. NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness. ASTM B-3 and B-8; UL 83 (/UL44);UL 719
NM-B (Flat) NM-B is commonly used for residential wiring of luminaries, devices and appliances. NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness. ASTM B-3 and B-8; UL 83 (/UL44); UL 719
NM (Round) NM is commonly used for residential wiring of luminaries, devices and appliances. NM may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness. ASTM B-3 and B-8;UL 83 (/UL44); UL 719
NM (Flat) NM is commonly used for residential wiring of luminaries, devices and appliances. NM may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness. ASTM B-3 and B-8     UL 83 (/UL44);UL 719
MC(GSIA) with XHHW-2 Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits;                                                                                                                                                                 UL 44; UL 1569
MC(GSIA) with XHHW-2 Inners PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits;                                                                                  UL 44; UL;1569
MC(GSIA) with THHN/THWN-2 Inners UL 83; UL 1569
MC(GSIA) with THHN/THWN-2 Inners PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings;Acceptable for power, lighting, control, and signal circuits; UL 83; UL 1569
MC(GSIA) with XHHW-2 AL Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits;  UL 44; UL 1569
MC(GSIA) with XHHW-2 AL PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits;                                                                          UL 44; UL;1569
MC(GSIA)with THHN/THWN-2 AL Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 83; UL 1569
MC(GSIA) with THHN/THWN-2 AL PVCJacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 83; UL 1569
MC(AIA) with XHHW-2 Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 44; UL 1569
MC(AIA) with XHHW-2 Inners PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 44; UL 1569
MC(AIA) with THHN/THWN-2 Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings;Acceptable for power, lighting, control, and signal circuits; UL 83; UL 1569
MC(AIA) with THHN/THWN-2 Inners PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 83; UL 1569
MC(AIA) with XHHW-2 AL Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 44; UL 1569
MC(AIA) with XHHW-2 AL–PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits UL 44; UL 1569
MC(AIA) with THHN/THWN-2 AL Inners Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 83; UL 1569
MC(AIA) with THHN/THWN-2 AL PVC Jacket Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings; Acceptable for power, lighting, control, and signal circuits; UL 83;  UL 1569
MHF Mobile Home Feeder Cable is used to provide power from the electrical disconnect to the distribution panel board in mobile home applications accordance with the requirements of the NEC NFPA 70, 2011 Edition ASTM B800 and B801  UL 44; UL 854 (USE-2); ICEA T-29-520
ACSR Used as bare overhead transmission cable and as primary and secondary distribution cable. B-230 Aluminum wire, 1350-H19 for Electrical Purposes;B-231 Aluminum Conductors, Concentric-Lay-Stranded;B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR);B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)  B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR) B-500 Metallic Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
RW90 600V RW90 building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit. CSA C22.2 NO.38-14  UL 44
RW75 600V RW75 building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit CSA C22.2 NO.38-14  UL 44
R90 600V R90 soft-annealed uncoated copper conductor is suitable for use in conduit and raceways installed underground in conduit CSA C22.2 NO.38-14  UL 44
RW90 AL 600V RW90 with aluminum alloy 8000 series conductors are intended for general purpose applications utilized in conduit and tubing underground in conduit CSA C22.2 NO.38-14  UL 44
RW75 AL 600V RW75 with aluminum alloy 8000 series conductors are intended for general purpose applications utilized in conduit and tubing underground in conduit CSA C22.2 NO.38-14  UL 44
R90 AL 600V R90 with aluminum alloy 8000 series conductors are suitable for use in conduit and raceways installed underground in conduit CSA C22.2 NO.38-14  UL 44
TECK90 1000V (AIA) Typical applications are primarily for power as well as lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, chemical plants and other industrial applications. ASTM B3, B8; CSA C22.2 No. 131   CSA C22.2 No. 2556 & No. 0.3.
TECK90 1000V (GSIA) Typical applications are primarily for power as well as lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, chemical plants and other industrial applications. ASTM B3, B8; CSA C22.2 No. 131   CSA C22.2 No. 2556 & No. 0.3.
TECK90 5000V (GSIA) Rated for installation in cable trays, duct banks, direct burial, ladder type cable troughs, continuous rigid cable supports, and is concrete encase able. ASTM B3, B8; CSA C22.2 No. 131   CSA C22.2 No. 174   CSA C22.2 No. 2556 & No. 0.3.
TECK90 5000V (AIA) Rated for installation in cable trays, duct banks, direct burial, ladder type cable troughs, continuous rigid cable supports, and is concrete encase able. ASTM B3, B8; CSA C22.2 No. 131   CSA C22.2 No. 174   CSA C22.2 No. 2556 & No. 0.3.
TECK90 AL 1000V(GSIA) Typical applications are primarily for power as well as lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, chemical plants and other industrial applications. ASTM B800, B801; CSA C22.2 No. 131   CSA C22.2 No. 2556 & No. 0.3.
TECK90 AL 1000V (AIA) Typical applications are primarily for power as well as lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, chemical plants and other industrial applications. ASTM B800, B801; CSA C22.2 No. 131   CSA C22.2 No. 2556 & No. 0.3.
TECK90 AL 5000V (GSIA) Rated for installation in cable trays, duct banks, direct burial adder type cable troughs, continuous rigid cable supports, and is concrete encase able. ASTM B800, B801; CSA C22.2 No. 131   CSA C22.2 No. 174   CSA C22.2 No. 2556 & No. 0.3.
TECK90 AL 5000V (AIA) Rated for installation in cable trays, duct banks, direct burial, ladder type cable troughs, continuous rigid cable supports, and is concrete encase able. ASTM B800, B801; CSA C22.2 No. 131   CSA C22.2 No. 174   CSA C22.2 No. 2556 & No. 0.3.

Contacto

    Tipo de producto(Opcional)

    Cableshilos de bobinadobobinasotros

    Lista de consultas(Opcional)

    Mensaje(Opcional)

    Actuation.Todos los derechos reservados (© Actuation. All Rights Reserved.)