XHHW-2 AL

600Volt. Aluminum Alloy ConductorXLPE Insulation Moisture /Heat /Low-Temp/Sunlight Resistant Flame RetardantThermoset Insulated Wire and Cable

APPLICATIONS

XHHW-2 AL building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the UsA National Electrical Code (NEC). XHHW-2 AL is permitted for 600-volt applications and can be used in wet or dry locations at temperatures not to exceed 90°C. It’s suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less. With the special insulation, the wire requires no lubrication for installation.

STANDARDS

Morn’s XHHW-2 AL complies with the following:

  • ASTM B800, B801, B836
  • UL44
  • USA National Electrical Code, NFPA 70, 2014 Edition

CONSTRUCTION

  • Stranded compressed/compacted AA-8000 series aluminum alloy
  • Cross-linked polyethylene (XLPE) insulation, abrasion /moisture /heat ow-temp /sunlightresistant, flame retardant

TECHNICAL PARAMETER LIST

THWN-2 AL

600Volt. Aluminum Alloy Conductor, PVCInsulation, Nylon Jacket, Moisture, Heat,Low-Temp,Sunlight Resistant, Flame Retardant,Thermoplastic Insulated Wire & Cable

APPLICATIONS

THWN-2 building wire with aluminum alloy 8000 series conductors are intended for general purpose applications asdefined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders,and branch circuits in commercial or industrial new construction or rewring for 600 volt applications. For applicationsrequiring it is appropriate for use in wet or dry locations at temperatures not to exceed 90’C. The wire is designed to beinstalled without application of a pulling lubricant.

STANDARDS

Morn’s THHN AL complies with the following:

  • ASTM B800, B801,B836
  • UL81

CONSTRUCTION

  • Stranded compacted/compressed AA-8000 series aluminum alloy
  • Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, sunlight resistant, flameretardant
  • Tough polyamide, Nylon

TECHNICAL PARAMETER LIST

SE-R with XHHW-2 AL Inners

600Volt. Aluminum Alloy Conductor, withXHHW-2 as Inners, Cross-linked Polyethylene(XLPE) Insulation Sunlight Resistant PVC JacketService Entrance Cable with Bare Neutral

APPLICATIONS

SE-R AL (Aluminum Alloy Conductor -Serice Entrance Cable Style R) is used to convey power from the service drop tothe meter base and from the meter base to the distribution panel board; however, it may be used in all applications whereSE-R AL cable is permitted. SE-R AL may be used in wet or dry above ground locations at temperatures not to exceed90°C. The voltage rating is 600 volts.

STANDARDS

Morn’s SE-R Cable with XHHW-2 AL inners complies with: ASTM B800, B801, B836

  • UL44(UL83/UL854)
  • UL 854
  • USA National Electrical Code, NFPA 70, 2014 Edition

CONSTRUCTION

  • Compressed/compacted stranded AA-8000 series aluminum alloy·
  • Cross-linked polyethylene (XLPE) insulation meeting the required thickness of Type XHHW-2rated for 90°C in wet or dry locations
  • Bare stranded AA-8000 series aluminum alloy ground conductor
  • Glass-reinforced polyester tape bedding
  • Sunlight resistant Polyvinyl chloride (PVC) jacket,

TECHNICAL PARAMETER LIST

SE-U with XHHW-2 AL Inners

600Volt. Aluminum Alloy Conductors, XHHW-2asInners Cross-linked Polyethylene (XLPE) InsulationSunlight Resistant PVC JacketService Entrance Cable with Concentric Neutral

APPLICATIONS

SE-U AL (Aluminum Alloy Conductor Service Entrance Cable Style U)is used to convey power from the service drop to themeter base and from the meter base to the distribution panel board however, it may be used in all applications whereSE-U AL cable is pemited. SE-U AL may be used in wet or dry above ground locations at temperatures not to exceed90°C. The voltage rating is 600 volts.

STANDARDS

Morn’s SE-U AL Cable complies with:

  • ASTM B800, B801, B836
  • UL 44(UL83/UL854)
  • UL854
  • USA National Electrical Code, NFPA 70, 2014 Edition

CONSTRUCTION

  • Compressed/compacted stranded AA-8000 series aluminum alloyCross-linked polyethylene (XLPE) insul
  • ation meeting the required thickness of Type XHHW-2rated for 90°C in wet or dry locations
  • Bare aluminum concentric neutral surround the phase conductors
  • Glass-reinforced polyester tape bedding
  • Sunlight resistant Polyvinyl chloride (PVC) jacket

TECHNICAL PARAMETER LIST

Single Conductor URD/USE-2

600 Volt. AL1350 Conductor, Cross-LinkedPolyethylene (XLPE) Insulation, Single ConductorSecondary UD (URD/USE-2)

APPLICATIONS

Secondary UD cable with single 1350-H1 Aluminum conductor suitable for use in underground service and secondary
distribution, Secondary UD is permitted for 600 volt or less applications, either direct burial or in ducts.

STANDARDS

Morn’s Secondary UD complies with the following:

  • ASTM B230,(B231, B609,B901)
  • ICEA S-105-692
  • UL854

CONSTRUCTION

  • Stranded compressed 1350-H19 aluminum
  • As phase conductor: cross-linked polyethylene (XLPE) insulation, abrasion, moisture, heat,low-temp, oil, gas, sunlight Resistant
  • As neutral conductor: cross-linked polyethylene (XLPE) insulation with yellow triple extrusionstrips, abrasion, moisture, heat, low-temp, oil, gas, sunlight resistant

TECHNICAL PARAMETER LIST

Further information upon request.

Contact Us