600Volt. Aluminum Alloy ConductorXLPE Insulation Moisture /Heat /Low-Temp/Sunlight Resistant Flame RetardantThermoset Insulated Wire and Cable
XHHW-2 AL building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the UsA National Electrical Code (NEC). XHHW-2 AL is permitted for 600-volt applications and can be used in wet or dry locations at temperatures not to exceed 90°C. It’s suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less. With the special insulation, the wire requires no lubrication for installation.
Morn’s XHHW-2 AL complies with the following:
600Volt. Aluminum Alloy Conductor, PVCInsulation, Nylon Jacket, Moisture, Heat,Low-Temp,Sunlight Resistant, Flame Retardant,Thermoplastic Insulated Wire & Cable
THWN-2 building wire with aluminum alloy 8000 series conductors are intended for general purpose applications asdefined by the USA National Electrical Code (NEC). It is permitted used in conduit and cable trays for services, feeders,and branch circuits in commercial or industrial new construction or rewring for 600 volt applications. For applicationsrequiring it is appropriate for use in wet or dry locations at temperatures not to exceed 90’C. The wire is designed to beinstalled without application of a pulling lubricant.
Morn’s THHN AL complies with the following:
600Volt. Aluminum Alloy Conductor, withXHHW-2 as Inners, Cross-linked Polyethylene(XLPE) Insulation Sunlight Resistant PVC JacketService Entrance Cable with Bare Neutral
SE-R AL (Aluminum Alloy Conductor -Serice Entrance Cable Style R) is used to convey power from the service drop tothe meter base and from the meter base to the distribution panel board; however, it may be used in all applications whereSE-R AL cable is permitted. SE-R AL may be used in wet or dry above ground locations at temperatures not to exceed90°C. The voltage rating is 600 volts.
Morn’s SE-R Cable with XHHW-2 AL inners complies with: ASTM B800, B801, B836
600Volt. Aluminum Alloy Conductors, XHHW-2asInners Cross-linked Polyethylene (XLPE) InsulationSunlight Resistant PVC JacketService Entrance Cable with Concentric Neutral
SE-U AL (Aluminum Alloy Conductor Service Entrance Cable Style U)is used to convey power from the service drop to themeter base and from the meter base to the distribution panel board however, it may be used in all applications whereSE-U AL cable is pemited. SE-U AL may be used in wet or dry above ground locations at temperatures not to exceed90°C. The voltage rating is 600 volts.
Morn’s SE-U AL Cable complies with:
600 Volt. AL1350 Conductor, Cross-LinkedPolyethylene (XLPE) Insulation, Single ConductorSecondary UD (URD/USE-2)
Secondary UD cable with single 1350-H1 Aluminum conductor suitable for use in underground service and secondary
distribution, Secondary UD is permitted for 600 volt or less applications, either direct burial or in ducts.
Morn’s Secondary UD complies with the following: